0x0506 - SetPowerPlantConfiguration
Description
powerPlantConfigurationList
Type: List
powerPlantConfigurationSeq
Type: Sequence
powerPlantIDRecord
Type: Record
Field # |
Field Name |
Type |
Units |
Optional |
Interpretation |
1 |
powerPlantID |
uint8 |
one |
false |
This is a unique ID for each powerplant and is provided by 4507 Report PowerPlant Capabilities message. |
powerPlantConfigurationVar
Type: Variant
gasEngineConfigurationRec
Type: Record
Field # |
Field Name |
Type |
Units |
Optional |
Interpretation |
1 |
PresenceVector |
uint8 |
|
|
|
2 |
powerState |
uint8 |
one |
false |
|
3 |
rpm |
uint16 |
one |
true |
Rotations per minute. Units here are one since JSIDL does not support RPM natively. |
4 |
throttle |
uint16 |
one |
true |
As a percent of maximum |
dieselEngineConfigurationRec
Type: Record
Field # |
Field Name |
Type |
Units |
Optional |
Interpretation |
1 |
PresenceVector |
uint8 |
|
|
|
2 |
powerState |
uint8 |
one |
false |
|
3 |
rpm |
uint16 |
one |
true |
Rotations per minute. Units here are one since JSIDL does not support RPM natively. |
4 |
throttle |
uint16 |
one |
true |
As a percent of maximum |
5 |
plugState |
uint8 |
one |
true |
|
batteryConfigurationRec
Type: Record
Field # |
Field Name |
Type |
Units |
Optional |
Interpretation |
1 |
powerState |
uint8 |
one |
false |
|
hydraulicConfigurationRec
Type: Record
Field # |
Field Name |
Type |
Units |
Optional |
Interpretation |
1 |
powerState |
uint8 |
one |
false |
|
fuelCellConfigurationRecs
Type: Record
Field # |
Field Name |
Type |
Units |
Optional |
Interpretation |
1 |
powerState |
uint8 |
one |
false |
|